1 • O/O - Override Open - Input for blow open or smoke ventilation application - Upon initiation of a closed signal from a fire/smoke alarm panel, the door will open and remain open until signal is terminated. Use with any JP-1 ground. 2 • RES 1 - Not used 3 • AUX2 - Auxiliary Two - This is one of two secondary initiating switch input contacts (JP-10 is the other.) Use with any JP-1 ground to initiate operation. 4 • GND - Ground 5 • INV - IN Vestibule - Used for vestibule function. This contact must be connected to the JP-1-6 terminal from another unit to receive an initiating signal. Use this contact with any JP-1 ground. 6 • OUTV - Out Vestibule - Used for vestibule function - This contact must be connected to terminal JP-5 of another unit to send an initiating signal. Use this contact with any JP-1 ground. 7 • GND - Ground 8 • RFT - Toggle (Maintained Hold Open) This input can be used with any normally open switch. The first initiation of this contact will open door and hold it open. A second initiation of this contact will release and close the door. Use with any JP-1 ground. 9 • GND - Ground 10 • AUX2 - Auxiliary Two - Same as JP1-3 above. 11 • GND - Ground 12 • PDET - Presence Detector - Permits wiring of a sensor to prevent a closed door from opening or a door that is fully open from closing. Use with any JP-1 ground. 13 • GND - Ground 14 • AUX1 - Auxiliary One - Primary initiating switch contact. Initiates door power cycle. For vestibule function, the switch on the initiating side of door is connected to this terminal. Use with any JP-1 ground.
JP-4 Terminal: (Output Controls) - electric strikes, latch retraction exit devices, mag locks, etc. 1 • GND - Ground 2 • +24VDC 3 • NO1 - Relay Contact - Normally open relay dry contact that is switched when any auxiliary inputs are initiated. Delay can be set for up to 12 seconds. Use with JP4-4 CO-1. 4 • CO1 - Relay Contact - Common relay contact for use with terminals JP4-3 and JP4-5. 5 • NC1 - Relay Contact - Normally closed relay contact that is switched when any auxiliary inputs are initiated. Delay can be set for up to 12 seconds. Use with JP4-4 CO1. 6 • NO2 - Alarm Delay - Normally open dry relay contact that is switched when any auxiliary inputs are initiated. The relay will stay switched for 30 or 60 seconds (selected by dip switch SW1-2 A/D). 7 • CO2 - Alarm Delay - Common contact for use with terminals JP4-6 and JP4-8. 8 • NC2 - Alarm Delay - Normally closed dry contact that is switched when any auxiliary inputs are initiated. The relay will stay switched for 30 or 60 seconds (selected by dip switch SW1-2 A/D).