ABS 200-1141-00 Solenoid Part Number is 200-1141-00 Model # TS1500X3-C-24Vdc - Intersol Industries Inc.

enlarge
enlarge
× This image is for a similar product but it will differ in size, color and/or other attributes.
ABS 200-1141-00 Solenoid Part Number is 200-1141-00 Model # TS1500X3-C-24Vdc - Intersol Industries Inc.
Image 2Click for 3d view
More from ABS
Price: $444.67 USD
Ships From
Comments (Optional)
In Stock (No Minimums):
Naples, FL Warehouse Qty: 23
Quick Ship - up to 10 units available to ship in 0 business days
For quantities beyond the "In Stock" above, the item(s) ships within 14 business days.

As of June 11th 2025 these solenoids are in manufacturing and are expected to be ready the middle of July 2025

1-773-809-3667

Sales
Technical Support
Product Description:
ABS 200-1141-00 Solenoid Part Number is 200-1141-00 Model # TS1500X3-C-24Vdc - Intersol Industries Inc.

Potted Circuit Breaker VON DUPRIN 050534

Additional Files:
Customer Images:
Questions and Answers
Q: What is the resistance value in ohms for the solenoid?
A: Between the red and black it 1.5 ohms and the white and black is 60.

The inrush current is and always was 16 Amps. You need a power supply that can provide a minimum of 18 amps for 1/3 second.

The black box (which we never provided) is an electronic switch. When first energized it supplies power to both coils for 1/3 second then the high current draw (1.5 ohm) coil is switched off leaving only the 60 ohm coil to hold the plunger in.

This solenoid will not work without the switch.

Q: We replaced the power supply as well as the solenoid. We are using an Adams Rite PS-EXIT device. The original power supply was a PS-LR which the specs state up to 16A pull-in. The PS-EXIT is rated at 17A pull-in. I would expect this is sufficient for the 1/3 second pull-in. We have not replaced the black box which I guess is this Von Duprin device I have found online. When I attach a meter to the solenoid between red and black, I see a voltage spike but cannot confirm the duration with just a meter. I also see the 24V between white and black for 2 seconds. The whole system functions fine if the door is already open, meaning the pull-in bar pulls in and stays open for 2 seconds. When the door is closed, it is like the load is too high to pull-in. Is this more likely then a mechanical adjustment issue?
A: Assuming you have eliminated the solenoid as the issue, and have not replaced the potted ciruit braker, indeed repalcing the VON DUPRIN 050534 EL Potted Circuit Breaker as seen here is the next component to replace:

Click Here

(Required, used to email you once question is answered.)
Customers who bought this item also bought:
VON DUPRIN 050534  EL Potted Circuit Breaker
z7905
VON DUPRIN 050534 EL Potted Circuit Breaker
Von Duprin
Price: $408.11
VON DUPRIN 050534 EL Potted Circuit Breaker
VON DUPRIN 050534
VON DUPRIN 050534 EL Potted Circuit Breaker for the 33A/35A and 98/99 Series. Package of 1.
Von Duprin
Price: $408.11
  • Watch Expert Advice on YouTube
  • Corporate Members of DHI
  • Member of NFPA.
  • Follow us on Facebook
  • AAADM Certified!
  • ALOA Certified!
  • Follow us on Twitter
  • DHI FDAI EDA Inspector
  • AIA
  • Follow us on Pinterest
  • ARL
  • Intertek Logo