Sargent 8410-F 36'' Narrow Concealed Vertical Rod Exit Device |
|
- ANSI A156.3 – 2001 Grade 1
- Door Types: Hollow metal or extruded aluminum. 1-3/4"(44mm) minimum thickness; 1-3/4"(44mm) minimum stile width required. Stile must be hollow with inside dimension of at least 1-3/8" (35mm) square
- Door Widths: E Rail - 24" to 32" (61cm to 81cm) No cutting required for 32" door; F Rail - 33" to 36" (84cm to 91cm) No cutting required for 36" door J Rail - 37" to 42" (94cm to 107cm) No cutting required for 42" door; G Rail - 43" to 48" (110cm to 122cm) No cutting required for 48" door
- Strike: 650 Top Strike & 606 Bottom Strike (Panic & Fire Rated)
- Dogging Feature: Hex key dogging standard; Cylinder dogging available (16-)
- Mounting Fasteners: Supplied standard with machine screws
- Top bolt: Stainless Steel
- Device Centerline from Finished Floor: 41” (1041 mm)
- Door/Opening Height: Must be specified - 120" (3048mm) Max Door Opening; 84" (2133mm) Standard for Turboship
- Center Case Dimensions: 8-3/8" (213mm) x 2-5/8" (67mm)
- Projection: Pushbar Neutral – 3" (76 mm); Pushbar Depressed – 2-1/8" (54 mm)
|
uired |
36'' Narrow Concealed Vertical Rod Exit Device Function |
|
- Designed for narrow stile applications such as full glass doors
- Concealed rods for security and aesthetics
- UL Fire and Panic listed
|
Handed arm is field-reversible |
Installation |
|
- Easy installation!
- Maintenance-free design
- Few moving parts – less wear
- Modular construction
- Rekeying is accomplished without removing device from door
|
|
|
Questions and Answers
Q: How do I cut down the rods? I have a7/0 device and installing onto a 6/8 tall door? A: From the Top Rod only, we recommend that the end with the pin hole be cut down to the desired length and then the hole be re drilled. Is there a follow up question that we can perhaps attempt to answer? We take deep pride in our technical expertise, as we know it separates us from our competition, so don't hesitate to ask.
Please reply to this email or contact our sales department here: Click Here if we can assist you by answering further questions or with entering this order and please let us know if there is anything else we can help with. Q: what number is electrical whips A: Are you asking what are the prefix numbers for the various Electric Options from Sargent for the 8400 series? If yes, the answer is:
AL- Alarm BT- Beacon™ PL- SARGuide™ Photoluminescent Coated TL- SARGuide™ Illuminated Touchpad 53- LX Latchbolt Monitor 54- Outside Lever Monitoring 55- Request-to-Exit Signal - Rail Monitoring 56- Remote Latch Retraction 57- Delay Egress & Electromagnets 58- Electric Dogging 59- Electroguard – Self Contained Delayed Egress This data is pulled from the standard Sargent Product Catalog as seen here: Download File
Is there a follow up question that we can perhaps attempt to answer? We take deep pride in our technical expertise, as we know it separates us from our competition, so don't hesitate to ask.
Please reply to this email or contact our sales department here: Click Here if we can assist you by answering further questions or with entering this order and please let us know if there is anything else we can help with.
(Required, used to email you once question is answered.)
Customer Reviews
There are no customer reviews yet.
|
|
|