Radix CTU14A0102-15000 UL 2196 2-Hour Fire Resistive Cable FPLR Unshielded 105°C/300V

enlarge
enlarge
× This image is for a similar product but it will differ in size, color and/or other attributes.
Radix CTU14A0102-15000 UL 2196 2-Hour Fire Resistive Cable FPLR Unshielded 105°C/300V
More from Radix
Price: $85,051.64 USD
Ships From
Comments (Optional)
This item is not in stock and typically ships in 15-20 business days.

1-844-809-3667

Sales
Technical Support
Product Description:
Radix logo

Radix CTU14A0102-15000 UL 2196 2-Hour Fire Resistive Cable FPLR Unshielded 105°C/300V

  • Certified to the harsh requirements of the UL2196 Test for Fire Resistive Cables, the DuraLife Dual-Rated CIC/CI cables ensure two-hour operation of critical systems in the event of a fire. The dual rating design offers the most versatility in meeting code survivability requirements in both in-conduit and free air installation scenarios.
  • Description: Dual-Rated CIC/CI Cable. UL/CAN (ULC) 2196 Certified/UL 1424 Listed. FHIT/ FHIT7 (ULC) System No. 28C. Low smoke, zero halogen design (LSZH).
  • Conductor: Oxygen-free bare copper (OFHC), solid and/or stranded
  • Insulation: Proprietary ceramifiable silicone rubber
  • Assembly: Color-coded black/red leads, 3 twists/foot
  • Jacket: Red low smoke/zero halogen FRPE with sequential footage markers (custom colors available/special order mins apply)
  • UL 1424 Listed FPLR/FPLR-CI (dual-rated) for Power-Limited Fire Alarm Circuits. Riser Rated. 300V/105°C classified
  • UL / CAN (ULC formerly S-139) Certified to UL 2196 2-hour fire rating in FHIT / FHIT7 28C
  • CSA Certified FAS90; CSA Std. C22.2 No. 208-14 FT4-ST1
  • UL Certified 2-hour fire rating as FPLR-CI for Free Air installed per NEC code
  • UL 444 Listed “CMR/CMR-CI” as Communications Cable
  • Fire alarm circuit integrity, emergency systems, and healthcare facilities (NEC Articles 760, 700 & 517)
  • Meets National Fire Protection Code (NFPA 70 & 72) fire alarm survivability circuit requirements
  • Meets National Fire Protection Code (NFPA 130 & 502) fire alarm survivability circuit requirements
  • Compliance tested to UL 1424 as suitable for use in applications requiring wet rating
  • Meets UL1685 and FT4/IEEE 1202 requirements
  • Tested for Sunlight Resistance in compliance with UL 2556 requirements
  • Suitable for 2-hour certified fire-resistive applications in EMT, IMC, or Phenolic conduit systems
  • UL Listed File No. E-241484. UL Fire Directory R-21213
  • Splice Allowance
  • Performance testing of cables, cold bend test of complete cable per defined testing parameters and UL 1424
  • NYC certified and CAFM approved