Q: What is the part number for the top latch assembly only from the 25-V ?
A: 650389 for panic and 650375 for fire. We have both in stock. Please reach out to our sales department and we will enter the order for you.
Is there a follow up question that we can perhaps attempt to answer? We take pride deep in our technical expertise, as we know it separates us from our competition, so don't hesitate to ask.
Please reply to this email or contact our sales department here:
Click Here
if we can assist you by answering further questions or with entering this order and please let us know if there is anything else we can help with.
Q: Can I convert an existing monarch 25 series 510L trim into the 510NL operation where I'm converting from a classroom function to and always locked storeroom function?
A: In fact you can.
The installation instructions can be seen here:
Download File
and here are the pieces that are necessary to both remove and the additional items that are need to be purchased in order to go about successfully converting the trim from a classroom function to a storeroom function are shown on the manufacturers marked up product catalog as seen here:
Download File
The two pieces that you need to order can be reviewed here:
Click Here
and here:
Q: Can a 25 series EO device work with any 25 series trim?
A: I can tell you that originally Monarch exit devices were absolutely built based on the function that they were required to perform, nowadays and for the last several years the devices are not built function specific and the exit only(EO) devices will accept any of the 500 series trims.
Q: Will the 25-C series rods and latches work on the old 18-C?
A: The internal rods and latches for the 25-C carried over from the older 18-C device so they can be used interchangeably.
Q: Will the 25-R or 25-V work with Simplex trim?
A: The 25-R or 25-V device does meet the trim input requirements set by KABA for their trim so the two should be compatible. However, the KABA trim has never been tested in house for the Falcon 25-R or 25-V device so which specific KABA model, any testing, compatibility concerns, or templating questions would best be addressed by KABA directly.
Q: How thick of door will the standard 24/25 series device mounting package work with?
A: Standard mounting packages are only for a 1 3/4" thick door. Door thickness other than 1 3/4" need to be specified when ordering the device.
Q: Can the Falcon 25-V be cut to fit on a 2' door?
A: The standard Falcon 25V vertical rod cannot be cut to fit on a 2 feet door opening.This device requires 2' 7 1/8" minimum door opening.
Falcon offers a device that can be used on a 2 feet door opening.
The 2’ Falcon 24/25 Surface Vertical devices can be used for fire rated assemblies. Keep in mind that NFPA 101 Section 7.2.1.7.1 requires the push pad extend not less than one-half of the width of the door. The push pad width is approximately 10 5/8” which means this device can be used on a door up tois a maximum of 21 1/4" wide and still meet this code.
Q: Do 25 series exit devices have a hurricane rating available?
A: Yes they do. Order the 25 device with the "HH" prefix as described in the device options in the Price Book.
Q: Will a 25R-L cover the door prep from a 18-R-L?
A: Yes, the holes on the door would be covered up by the 25-R-L device.
The (4) center case mounting holes are in the same location but there are some small modifications that will be needed like the 3/4" dia. hole at device CL for the main cam clearance shown on the 25-R Template as seen here:
Download File
and the now (2) mounting holes at the end cap end of the device shown on step 14 of the 25-R Instructions.
Q: Can a 24-R, 24-V, 25-R, or 25-V device use just a cylinder on the pull side for NL-OP function?
A: This is possible. A rim cylinder with cylinder anchor plate is used (anchor plate provided with rim cylinder package). No other special components are required. Order device as NL-OP. An exit-only device will be shipped, along with a template/instruction sheet that indicates how to mount the rim cylinder. Pricing is same as an exit-only device.
For metal doors, prep door according to the 24R/V NL-OP Template or the 25R/V NL-OP Template and for wood doors use 24R/V NL-OP Wood Template or 25R/V NL-OP Wood Template as seen here:
Download File
Q: Is dogging available w/ EL option on 24 or 25 series devices?
A: This option is not available as the solenoid is in the mechanism case where the dogging components would go. An HD-EL solenoid is not available, and Special Dogging(SD) is not an option for the Falcon line even via Engineering Specials.
Electrical dooging is an option by using a PS914 x 2RS board with a switch to maintain dogging when needed.
Q: What BHMA Grade is the Falcon 25 Series exit device?
A: Falcon F-25 series is the UL Rated Fire Exit Hardware device is a ANSI/BHMA A156.3 Standard for Grade 1 device and a copy of the BHMA Directory Listing can be viewed in the online Certified Directory on the BHMA web site as seen here:
Click Here
though contacting BHMA may be required.
Q: What are the minimum door widths for the Falcon 25 devices?
A: As a general rule, the 3 Falcon 25 device will fit on a 32" door opening.
Q: What cylinder is used in the Falcon 24/25 exit alarm kit?
A: The Exit Alarm takes a 1 1/8" Mortise cylinder with a straight cam. See first page of Exit Alarm installation instructions as seen here: