Hager 4501 SVR 0 48" x 84" US10 1-3-4" ELR

copy to clipboard

Hager 4501 SVR 0 48" x 84" US10 1-3-4" ELR Non-Fire Rated 48" x 84" Electric Latch Retraction Function Heavy Duty Electrified Surface Vertical Rod Device - Satin Bronze

enlarge
enlarge
× This image is for a similar product but it will differ in size, color and/or other attributes.
Hager 4501 SVR 0 48" x 84" US10 1-3-4" ELR Non-Fire Rated 48" x 84"  Electric Latch Retraction Function Heavy Duty Electrified Surface Vertical Rod Device - Satin Bronze
More from Hager
Price: $2,221.51 USD
Ships From
Comments (Optional)
This item is not in stock and typically ships in 15 business days.

1-844-809-3667

Sales
Technical Support
Product Description:
Hager 4501 SVR 0 48" x 84" US10 1-3-4" ELR Non-Fire Rated 48" x 84" Electric Latch Retraction Function Heavy Duty Electrified Surface Vertical Rod Device - Satin Bronze
  • Hager 4500 Series Grade 1 exit device meets Life Safety codes and Fire Safety requirements providing a perfect fit for use in commercial office buildings, medical and educational facilities, as well as hospitality structures
  • The 4500 Series is BHMA-Certified to the requirements of ANSI 156.3 for Grade 1 exit devices and is UL 305 Panic Listed and UL and cUL Listed for up to 3 hour rated fire doors for both rim and surface vertical rod
  • These devices have also met the requirements of ANSI A250.13 to be listed as a Severe Windstorm Component
  • The 4500 Series exit device offers a lifetime warranty to provide peace of mind from the distributors to the building owner
  • Product Group: 4500 Series Grade 1 Exit Devices
  • Product Type: Surface Vertical Rod (SVR)
  • Rating: Non-Fire Rated (0)
  • Size: 48" x 84" (48" (1219 mm) Door Width; 84" (2134 mm) Door Height)
  • Finish: Satin Bronze (US10)
  • Door Thickness: 1-3/4" (44 mm)
  • Function: Electric Latch Retraction (ELR)




Additional Product Information
  • 4500 Series Exit Devices
  • Certifications:
    • BHMA Certified ANSI A156.3 Grade 1
    • UL305 Listed for Panic Hardware
    • UL/cUL Listed for up to 3 hours for "A" label doors up to 10' in height
    • UL10C Positive Pressure Rated
    • UL10B Neutral Pressure Rated
    • Complies with ANSI A117.1 for accessible buildings and facilities
    • ANSI A250.13 Severe Windstorm Resistant Component (requires use of windstorm reinforcing bracket, 2-649-0154, on Rim device)
    • Miami Dade NOA #11-1219.14
  • Applications: Heavy Duty Commercial
  • Finishes: US3, US4, US10, US10B, US26, US26D, US32D, Trim is not available in US32D
  • Covers: Stainless steel, zinc
  • Cover Tube: Aluminum
  • End Caps: Zinc
  • Door Width:
    • 36" door minimum for devices with electric latch retraction, electric dogging, or alarm kit
    • 48" device is field sizeable to 40" door with electric latch retraction, electric dogging, or alarm kit
  • Door Height:
    • 84" (2134 mm) - standard
    • 96" (2438 mm) - optional
    • 120" (3048 mm) - optional
  • Door Thickness: 1-3/4" (44 mm) - standard up to 3", except with night latch which is 2-1/2"
  • Stile Width:
    • 5-3/8" (137 mm) - Minimum stile width required for single doors and standard 5/8" (16 mm) stop
    • 5-3/4" (137 mm) - Minimum stile width required for double door and 2" (51 mm) mullion
    • 4-7/8" (124 mm) - Minimum stile width required for double door
    • All stile widths are measured from the door edge
  • Trim:
    • Escutcheon trim
    • Pull plate trim (excluding 45PT)
  • Fasteners:
    • Wood and machine screws
    • Thru-bolts
  • Latchbolt:
    • 1/2" (12.7 mm) throw - top and bottom latches
    • Stainless Steel with dead latch
  • Strikes:
    • Steel with plated rollers - Standard
    • Overlapping strike for pair of doors
    • Surface applied to frame with slotted holes for easy adjustment
  • Function:
    • ELR - Electric Latch Retraction
    • ED - Electric Dogging
    • RX - Request to Exit
    • ELRX - Electric Latch Retraction with Request to Exit
    • EDRX - Electric Dogging with Request to Exit
    • ALK - Alarm Kit
    • AI - Authorized Ingress
    • LM - Latch Bolt Monitor
    • MLR - Motor Driven Electric Latch Retraction (Field Installation Kit 2-649-5007)
    • MLRX - Motor Driven Electric Latch Retraction with Request to Exit
  • Electrical Specifications:
    • ED; .225 AMP @ 24 Volt +/- 2 V
    • RX, LM or AI; 125 VAC (3 AMP current); 30 VDC (2 AMP current)
    • ELR; requires 2901/2902 power supply
    • MLR; 1 AMP in rush @ 24 VDC +/- 2 V
  • Wire Requirements:
    • EL and EU functions require 2 wires for power per device
    • Status switches (i.e. RX, LM, etc.) require 2 wires per switch to monitor a normally open (NO) or normally closed (NC) position
    • All devices provide 3 wires per switch so both NO and NC positions can be monitored
    • Monitoring both positions will require 3 wires per switch
  • Case Quantity: 3
  • Sold: Per Piece
  • Note: Recommended to be used on appropriately reinforced doors
  • Warranty: One-year on electrified components. Lifetime on hardware components
SVR Device Profile
Questions and Answers
There are currently no questions or answers.
(Required, used to email you once question is answered.)
  • Watch Expert Advice on YouTube
  • Corporate Members of DHI
  • Member of NFPA.
  • Follow us on Facebook
  • AAADM Certified!
  • ALOA Certified!
  • Follow us on Twitter
  • DHI FDAI EDA Inspector
  • AIA
  • Follow us on Pinterest
  • ARL
  • Intertek Logo