Fire-Lite ES-50X Addressable Fire Alarm Control Panel - 50 Point

Product Information:
  • The ES-50X is the latest intelligent addressable fire alarm control panel (FACP) from Fire Lite Alarms and is a direct replacement for the MS-9050UD/LS. The ES-50X comes with a pre-installed communi-cator and supports up to 50 addressable devices in any combination of detectors or modules. With an extensive list of powerful features, the ES-50X programs just like Fire Lite’s other addressable panels, yet fits into applications previously served only by conventional panels
  • Listed to UL Standard 864, 10th edition
  • Pre-installed IPOTS-COM Ethernet IP and POTS (Plain Old Telephone Service) Central Station Communicator
  • Optional CELL-MOD or CELL-CAB-FL GSM Central Station Communicator over AlarmNet®
  • Compatible with SWIFT® wireless devices
  • Auto-programming (learn mode) reduces installation time. Reports two devices set to the same address
  • Two independently programmable, built-in Style Z (Class A) or Style Y (Class B) NAC circuits
  • Selectable strobe synchronization for System Sensor, Wheelock, and Gentex devices
  • Notification Appliance Circuit End of Line resistor matching
  • Four programmable function keys for ease of maintenance
  • Two programmable relays and one fixed trouble relay
  • Built-in Programmer
  • Integral 80-character LCD display with backlighting
  • Real-time clock/calendar with automatic daylight savings control
  • History file with 1,000 event capacity
  • Addressable sounder base
  • Multi-criteria detector (smoke, heat, CO) with programmable response
  • Control module delay timer
  • Automatic detector sensitivity testing (NFPA 72 compliant)
  • Automatic device type-code verification
  • Point trouble identification
  • Waterflow selection per module point
  • Alarm verification selection per detector point
  • Maintenance alert warns when smoke detector dust accumulation is excessive
  • One-person audible or silent walktest with walktest log & printout
  • System alarm verification selection per detector point
  • PAS (Positive Alarm Sequence) and Pre-signal per point (NFPA 72 compliant)
  • Up to 16 ANN-BUS annunciators- 8 per each ANN-Bus
  • Remote Acknowledge, Alarm Silence, Reset and Drill via addressable modules or remote annunciator
  • Upload/Download of program and data via USB with optional FSTools Programming Utility
  • UNSPSC Code: 46171600

Documents:
Questions and Answers
There are currently no questions or answers.
(Required, used to email you once question is answered.)
  • Watch Expert Advice on YouTube
  • Corporate Members of DHI
  • Member of NFPA.
  • Follow us on Facebook
  • AAADM Certified!
  • ALOA Certified!
  • Follow us on Twitter
  • DHI FDAI EDA Inspector
  • AIA
  • Follow us on Pinterest
  • ARL
  • Intertek Logo