Home > Metal Doors > Steel Stiffened > Ceco > 18ga > Ceco MS18CRS30 70 F

Ceco MS18CRS30 70 F

copy to clipboard

Ceco MS18CRS30 70 F 3/0 x 7/0 Medallion 18 Gauge CRS Steel Stiffened Core Door

enlarge
enlarge
× This image is for a similar product but it will differ in size, color and/or other attributes.
Ceco MS18CRS30 70 F 3/0 x 7/0 Medallion 18 Gauge CRS Steel Stiffened Core Door
More from Ceco
Price: $657.69 USD
Ships From
Comments (Optional)
This item is not in stock and typically ships in 5 business days.

1-844-809-3667

Sales
Technical Support
Product Description:
3/0 x 7/0 Medallion Steel Stiffened Core Door
  • 3/0 x 7/0
  • 18 gauge cold rolled steel
  • 1-3/4" (44.4 mm) custom construction seamless design - rated for heavy-duty to maximum-duty use
  • Designed for high frequency, severe traffic openings
  • 22 gage vertical steel stiffeners spaced 6" apart, welded to face sheets every 5"
  • Fully welded edge seams enhance strength and appearance
  • Fiberglass insulation to limit thermal and sound transmission
  • Lock and hinge edge beveled 1/8" in 2" (1:16)
  • Inverted end channels welded to both face sheets
  • 7 gage (4.2 mm) steel hinge reinforcement
  • Neutral prime base coat
  • Ceco Part: D000351 (LH LC1) / D000053 (LH LM0) / D000352 (RH LC1) / D000054 (RH LM0)
Performance
  • Core material: Steel Stiffeners/Fiberglass batt insulation
  • Thermal Characteristics: U Factor 0.69, R Factor 1.44
  • Sound Transmission: STC 38 (18 gage operable)
  • Physical Endurance (Cycle Testing)
    • Level B
    • 500,000 cycles
Handing Chart
Questions and Answers
Q: can I get a 3d model of the door
A: Contact Ceco for this:

Click Here

Q: What causes the top rod case to pull away from or strip out of the face of a steel door?
A: Hardware falling off a door is caused by one or all of the following issues:

  • Field abuse
  • Improper internal reinforcements in the door
  • Improper field preparation
  • The top or bottom rod case can strip out of (or pull away from) a steel door face if the door is not properly (internally) reinforced.

    Internal exit device reinforcements are construction options to a steel door.

    When the required exit device preparation is specified and ordered with the door, the door usually would include the internal reinforcements

    When ordering the door, an option does exist for "Thru-bolt" attachment

    To rectify a field problem, assuming the door did not have adequate (or lacks) internal reinforcing and/or the device was only attached with sheet metal or machine screws, the device should be re-installed using either Thru-bolt or Sex bolt attachment.