All exit devices shall be DORMA 9000 Series rim, mortise,
surface, or concealed vertical rod devices. All devices to have
heavy-duty cast chassis.
All device touchbar, rail, and cover
assemblies shall be constructed of heavy gauge solid wrought
materials for true architectural finishes or color coated finishes
where applicable.
The partial-length touchpad assembly shall
permit field installation of options such as cylinder dogging and
exit alarm.
Non-labeled units to have hex-key dogging standard.
Fire rated versions shall be available for labeled applications.
All
surface vertical rod devices shall have pullman type top latch
bolts and round slidebolt bottom latches.
All devices to have
deadlocking latch bolts with 3/4" throw where applicable.
All
units shall offer a full range of free wheeling operational trim,
except mortise devices.
All units shall offer optional rigid and
clutch-style trim, where applicable.
All devices to be furnished
with appropriate mounting hardware including both wood and
machine screws, as well as sex nuts where required.
Optional Specifications: |
Non-labeled devices to have cylinder dogging. Mortise cylinder
not included. Specify CD. |
All surface/concealed vertical rod devices to have pullman type
bottom latch bolt. Specify PB. |
All surface/concealed vertical rod devices to have extended top
rod up to 10'. Specify ETR. |
All surface/concealed vertical rod devices to be furnished less
bottom rod. Specify LB. |
Devices to have electric latch bolt retraction to provide remote
access from the secure side of door. Can also be used in
conjunction with low energy/automatic door operator. Specify ES
(ES must be powered by PS-501 power supply and ES-105
power transfer). |
Devices to be furnished with two switches in the touchbar to
provide notification when touchbar is depressed. Specify MS. |
Devices to have latch monitor with monitor switches in
touchbar. Specify LM/MS. |
Devices to have latch monitor with monitor switches and a
bypass to permit authorized exit. Specify LM/MS BP. |
Devices to have one of the following exit alarm options:
battery-powered exit alarm (BPA), battery-powered exit alarm with
a 4-minute reset (BPAR), or direct hard-wired exit alarm (DWA). |
Devices to use a glass lite shim kit to raise the device from the
door surface to accommodate glass light molding. Specify
GK9000. |
All devices for labeled wood or composite doors to be
furnished with sex bolts. Specify SNB. |
All concealed vertical rod exit devices installed in wood doors
to be furnished with appropriate brackets, fasteners, and
templates for wood door applications. Specify WD (9100 only). |
All devices to be furnished with rigid trim. Specify R after trim
number. |
All devices to be furnished with clutch-style lever trim. Specify
C after lever trim number. |
Devices to have a latch monitor to report the latch bolt status.
Specify LM. |
Standard Strike |
Optional Strikes |
|
|
Mortise Lock |
|
Vertical Reference |
|
General Information |
• Partial width touchbar and
rail, chassis, and latch bolt
covers are fabricated from
brass, bronze, aluminum,
steel, or stainless steel |
• End cap for touchbar
assembly furnished in
complementary finish. |
• Some models handed
depending on outside
operating trim and function. |
• Most devices easily
field-reversible. |
• Fasteners provided for
metal and wood door
applications. |
• Free wheeling, vandalresistant
trim standard. |
Features |
Model
9300 |
Model
9400 |
Model
9500 |
U.L. Listed for Hazard |
|
|
|
U.L. Listed for Labeled Fire Doors (prefix F) |
|
|
|
Size “A” Doors 34" to 48" Wide |
|
|
|
Size “B” Doors 28" to 36" Wide |
|
|
|
Size “C” Doors 22" to 36" Wide |
|
|
|
Door Height up to 8' |
|
|
|
Door Height up to 10' (specify ETR) |
NA |
|
NA |
Door Thickness 1-3/4" to 2-1/4" |
|
|
|
|
|
NA |
NA |
Device Non-Handed |
NA |
|
NA |
Device Handed but Field-Reversible |
NA |
NA |
|
Device Handed, Not Reversible |
|
|
|
Hex Key Dogging (non-listed units only) |
|
|
|
Cylinder Dogging (non-listed units only) |
NA |
|
NA |
Round Bottom Slide Bolt |
NA |
|
NA |
Deadlocking Pullman Type Bottom Latchbolt (specify PB) |
NA |
|
NA |
Less Bottom Rod (specify LB) |
|
|
|
Electric Latchbolt Retraction (specify ES) |
|
|
|
Monitor Switch in Touchbar (specify MS) |
|
|
|
Latch bolt Monitor (specify LM) |
|
|
|
Latch Monitor/Monitor Switch (specify LM/MS) |
|
|
|
Latch Monitor/Monitor Switch with Bypass
(specify LM/MS BP) |
|
|
|
Exit Alarm (specify BPA, BPAR or DWA) |
|
|
|
|