Dorma 9400 |
9400 Surface Vertical Rod Exit Devices
|
|
Manufacturer: Dorma |
Price: $1,476.19
|
|
|
|
|
|
|
|
|
|
|
This product review video is for a similar product but it will differ in size, color and/or other attribute. We still feel the video will be of value to you.
|
|
 |
|
 |
|
|
Overview |
All exit devices shall be DORMA 9000 Series rim, mortise, surface, or concealed vertical
rod devices.
All devices to have heavy-duty cast chassis.
All device touchbar, rail, and cover assemblies shall be constructed of heavy
gauge solid wrought materials for true architectural finishes or color coated
finishes where applicable.
The partial-length touchpad assembly shall permit field installation of options
such as cylinder dogging and exit alarm
Non-labeled units to have hex-key dogging standard.
Fire rated versions shall be available for labeled applications.
All surface vertical rod devices shall have pullman type top latch bolts and round
slidebolt bottom latches.
All devices to have deadlocking latch bolts with 3/4" throw where applicable.
All units shall offer a full range of free wheeling operational trim, except mortise
devices.
All units shall offer optional
rigid and clutch-style trim,
where applicable.
All devices to be
furnished with
appropriate
mounting
hardware including
both wood and machine
screws, as well as sex
nuts where required.
|
9400 Surface Vertical Rod Exit Devices
|
|
The 9400 and F9400 provide heavy-duty, secure, two-point
latching at the top and bottom of the opening. Both the 9400
and F9400 Series feature a patented latch design for reliable,
secure operation. The F9400 devices are U.L.-listed for three
hour fire door applications.
|
|
Certification |
The DORMA 9000 Series is listed by U.L. and C.U.L. under
their continuing reinspection programs and conforms to
standards U.L. 10C and U.B.C. 7-2 (1997) positive pressure
testing.
The DORMA 9000 Series is BHMA certified to the
requirements of ANSI A156.3 for Grade 1 exit devices. |
Specification |
All exit devices shall be DORMA 9000 Series rim, mortise,
surface, or concealed vertical rod devices. All devices to have
heavy-duty cast chassis.
All device touchbar, rail, and cover
assemblies shall be constructed of heavy gauge solid wrought
materials for true architectural finishes or color coated finishes
where applicable.
The partial-length touchpad assembly shall
permit field installation of options such as cylinder dogging and
exit alarm.
Non-labeled units to have hex-key dogging standard.
Fire rated versions shall be available for labeled applications.
All
surface vertical rod devices shall have pullman type top latch
bolts and round slidebolt bottom latches.
All devices to have
deadlocking latch bolts with 3/4" throw where applicable.
All
units shall offer a full range of free wheeling operational trim,
except mortise devices.
All units shall offer optional rigid and
clutch-style trim, where applicable.
All devices to be furnished
with appropriate mounting hardware including both wood and
machine screws, as well as sex nuts where required.
Optional Specifications: |
Non-labeled devices to have cylinder dogging. Mortise cylinder
not included. Specify CD. |
All surface/concealed vertical rod devices to have pullman type
bottom latch bolt. Specify PB. |
All surface/concealed vertical rod devices to have extended top
rod up to 10'. Specify ETR. |
All surface/concealed vertical rod devices to be furnished less
bottom rod. Specify LB. |
Devices to have electric latch bolt retraction to provide remote
access from the secure side of door. Can also be used in
conjunction with low energy/automatic door operator. Specify ES
(ES must be powered by PS-501 power supply and ES-105
power transfer). |
Devices to be furnished with two switches in the touchbar to
provide notification when touchbar is depressed. Specify MS. |
Devices to have latch monitor with monitor switches in
touchbar. Specify LM/MS. |
Devices to have latch monitor with monitor switches and a
bypass to permit authorized exit. Specify LM/MS BP. |
Devices to have one of the following exit alarm options:
battery-powered exit alarm (BPA), battery-powered exit alarm with
a 4-minute reset (BPAR), or direct hard-wired exit alarm (DWA). |
Devices to use a glass lite shim kit to raise the device from the
door surface to accommodate glass light molding. Specify
GK9000. |
All devices for labeled wood or composite doors to be
furnished with sex bolts. Specify SNB. |
All concealed vertical rod exit devices installed in wood doors
to be furnished with appropriate brackets, fasteners, and
templates for wood door applications. Specify WD (9100 only). |
All devices to be furnished with rigid trim. Specify R after trim
number. |
All devices to be furnished with clutch-style lever trim. Specify
C after lever trim number. |
Devices to have a latch monitor to report the latch bolt status.
Specify LM. |
Standard Strike |
|
|
Optional Strikes |
|
|
|
|
Minimum Stile and Vertical Reference |
|
|
General Information |
• Partial width touchbar and
rail, chassis, and latch bolt
covers are fabricated from
brass, bronze, aluminum,
steel, or stainless steel |
• End cap for touchbar
assembly furnished in
complementary finish. |
• Some models handed
depending on outside
operating trim and function. |
• Most devices easily
field-reversible. |
• Fasteners provided for
metal and wood door
applications. |
• Free wheeling, vandalresistant
trim standard. |
Features |
Model
9300 |
Model
9400 |
Model
9500 |
U.L. Listed for Hazard |
|
|
|
U.L. Listed for Labeled Fire Doors (prefix F) |
|
|
|
Size “A” Doors 34" to 48" Wide |
|
|
|
Size “B” Doors 28" to 36" Wide |
|
|
|
Size “C” Doors 22" to 36" Wide |
|
|
|
Door Height up to 8' |
|
|
|
Door Height up to 10' (specify ETR) |
NA |
|
NA |
Door Thickness 1-3/4" to 2-1/4" |
|
|
|
|
|
NA |
NA |
Device Non-Handed |
NA |
|
NA |
Device Handed but Field-Reversible |
NA |
NA |
|
Device Handed, Not Reversible |
|
|
|
Hex Key Dogging (non-listed units only) |
|
|
|
Cylinder Dogging (non-listed units only) |
NA |
|
NA |
Round Bottom Slide Bolt |
NA |
|
NA |
Deadlocking Pullman Type Bottom Latchbolt (specify PB) |
NA |
|
NA |
Less Bottom Rod (specify LB) |
|
|
|
Electric Latchbolt Retraction (specify ES) |
|
|
|
Monitor Switch in Touchbar (specify MS) |
|
|
|
Latch bolt Monitor (specify LM) |
|
|
|
Latch Monitor/Monitor Switch (specify LM/MS) |
|
|
|
Latch Monitor/Monitor Switch with Bypass
(specify LM/MS BP) |
|
|
|
Exit Alarm (specify BPA, BPAR or DWA) |
|
|
|
|
ANSI
Function |
Function
Description |
|
Type 2 Surface Vertical Rod
Exit Device |
01 |
Exit Only –No Trim |
9300 or F9300 |
9400 or F9400 |
02 |
Entrance by trim when actuating bar is locked down. |
9300 x (trim)
V102/V302
PTT02/PRT02
YR02R/YT02R/YC02R/YK02R
|
9400 x (trim)
V102/V302
PTT02/PRT02
YR02R/YT02R/YC02R/YK02R |
03 |
Entrance by trim when latch bolt is retracted by key. Key removable only when locked. |
9300 or F9300 x (trim)
VO03/V103/V303, YO03
NPT03/PTT03/PRT03
YR03R/YT03R/YC03R/YK03R
R03/R03IC/C03/C03IC/K03/K03IC
POF03HDA
|
9400 or F9400 x (trim)
VO03/V103/V303, YO03
NPT03/PTT03/PRT03
YR03R/YT03R/YC03R/YK03R
R03/R03IC/C03/C03IC/K03/K03IC
--- |
04 |
Entrance by trim when latch bolt is retracted by key or set in retracted position by key. |
9300CD x (trim)
VO03/V103/V303, YO03
NPT03/PTT03/PRT03
YR03R/YT03R/YC03R/YK03R
R03/R03IC/C03/C03IC/K03/K03IC
POF03HDA
|
9400CD x (trim)
VO03/V103/V303, YO03
NPT03/PTT03/PRT03
YR03R/YT03R/YC03R/YK03R
R03/R03IC/C03/C03IC/K03/K03IC
---
|
05 |
Entrance by thumbpiece. Key locks or unlocks trim. |
9300 or F9300 x (trim)
HTT05/HRT05
|
9400 or F9400 x (trim)
HTT05/HRT05
|
06 |
Entrance by thumbpiece only when released by key. Key removeable only when trim is locked. |
9300 or F9300 x (trim)
HTT06/HRT06
|
9400 or F9400 x (trim)
HTT06/HRT06
|
08 |
Entrance by knob or lever. Key locks or unlocks knob or lever. |
9300 or F9300 x (trim)
YR08/YT08/YC08/YK08
YR08C/YT08C/YC08C
R08/R08IC/C08/C08IC/K08/K08IC
|
9400 or F9400 x (trim)
YR08/YT08/YC08/YK08
YR08C/YT08C/YC08C
R08/R08IC/C08/C08IC/K08/K08IC
|
08x08 |
Entrance by lever. OS or IS
key locks or unlocks lever.
|
F9300 x (trim)
YR08x08
|
---
---
|
09 |
Entrance by knob or lever only when released by key. Key removable only when locked. |
9300 or F9300 x (trim)
YR09/YT09/YC09/YK09
YR09C/YT09C/YC09C
|
9400 or F9400 x (trim)
YR09/YT09/YC09/YK09
YR09C/YT09C/YC09C
|
22 |
Entrance by thumbpiece (no cylinder). Trim always active. |
9300 or F9300 x (trim)
HRT22/HTT22
|
9400 or F9400 x (trim)
HRT22/HTT22
|
23 |
Entrance by knob or lever (no cylinder). Trim always active. |
9300 or F9300 x (trim)
YC23/YR23/YT23/YK23
C23/R23/K23
|
9400 or F9400 x (trim)
YC23/YR23/YT23/YK23
C23/R23/K23
|
ANSI
Function
|
Function
Description
|
Type 3
Mortise Exit Device |
Type 7/8
Wood/Metal Door Concealed Vertical Rod Exit Device
|
01 |
Exit Only – No Trim |
9500 or F9500 |
9100 or F9100 |
02 |
Entrance by trim when
actuating bar is locked
down.
|
9500 x (trim)
V102M/V302M
PTT02M/PRT02M
YR02R/YT02R/YC02R/YK02R
|
9100 x (trim)
V102CV/V302CV
PTT02CV/PRT02CV
YR02R/YT02R/YC02R/YK02R
|
03 |
Entrance by trim when
latch bolt is retracted by
key. Key removable only
when locked.
|
9500 or F9500 x (trim)
VO03M/V103M/V303M, YO03M
NPT03M/PTT03M/PRT03M
YR03MR/YT03MR/YC03MR/YK03MR
---
|
9100 or F9100 x (trim)
VO03CV/V103CV/V303CV, YO03
NPT03CV/PTT03CV/PRT03CV
YR03R/YT03R/YC03R/YK03R
R03/R03IC/C03/C03IC/K03/K03IC
|
04 |
Entrance by trim when
latch bolt is retracted
by key or set in retracted
position by key.
|
9500CD x (trim)
VO03M/V103M/V303M, YO03M
NPT03M/PTT03M/PRT03M
YR03MR/YT03MR/YC03MR/YK03MR
---
|
9100CD x (trim)
VO03CV/V103CV/V303CV, YO03
NPT03CV/PTT03CV/PRT03CV
YR03R/YT03R/YC03R/YK03R
R03/R03IC/C03/C03IC/K03/K03IC
|
05 |
Entrance by thumbpiece. Key locks or unlocks thumbpiece. |
9500 or F9500 x (trim)
HTT05M/HRT05M
|
9100 or F9100 x (trim)
HTT05CV/HRT05CV
|
06 |
Entrance by thumbpiece only when released by key. Key removable only when locked. |
---
---
|
9100 or F9100 x (trim)
HTT06CV/HRT06CV
|
08 |
Entrance by knob or lever. Key locks or unlocks knob or lever. |
9500 or F9500 x (trim)
YR08M/YT08M/YC08M/YK08M
YR08MC/YT08MC/YC08MC
---
|
9100 or F9100 x (trim)
YR08/YT08/YC08/YK08
YR08C/YT08C/YC08C
R08/R08IC/C08/C08IC/K08/K08IC
|
09 |
Entrance by knob or lever only when released by key. Key removable only when locked. |
---
---
---
|
9100 or F9100 x (trim)
YR09/YT09/YC09/YK09
YR09C/YT09C/YC09C
|
22 |
Entrance by thumbpiece (no cylinder). Trim always active. |
>9500 or F9500 x (trim)
HRT22M/HTT22M
|
9100 or F9100 x (trim)
HRT22CV/HTT22CV
|
23 |
Entrance by knob or lever
(no cylinder). Trim always
active.
|
9500 or F9500 x (trim)
YC23M/YR23M/YT23M/YK23M
---
|
9100 or F9100 x (trim)
YC23/YR23/YT23/YK23
C23/R23/K23
|
How to Order |
To order, list options, model number, trim, strikes, hand, and
finish. |
Options: |
|
(R) Rigid Trim |
(C) Clutch Style Lever Trim |
(BPA) Battery Powered Exit Alarm |
(BPAR) Battery Powered Exit Alarm, (4) minute reset |
(DWA) Direct Wired Exit Alarm |
(CD) Cylinder Dogging |
(ES) Latch Retraction |
(ETR) Top Rod Extension – vertical rod only |
(GK9000) Glass Lite Shim Kit |
(LB) Less Bottom Rod – vertical rod only |
(LM) Latch Monitor |
(MD) Magnetic Dogging |
(MS) Monitor Switch |
(LM/MS) Latch Monitor/Monitor Switch |
(LM/MS BP) Latch Monitor/Monitor Switch with Bypass |
(PB) Pullman Bottom Latch – vertical rod only |
(SNB) Sex Nuts – specify quantity |
(WD) Wood Door Package (9100 only) |
(HC) Hurricane Rated Device (9300 and 9400) |
Model |
Door
Material
|
Max. Door
Opening
|
Door Ratings |
Applications |
|
Single door |
Rim
9300
|
Wood/ Steel |
4' x 8'' |
Devices are panic listed only |
Surface applied
(1) point latching |
|
Rim F9300  |
Steel |
4' x 8' |
3 Hour |
Wood |
4' x 8' |
1-1/2 Hour |
Surface Vertical Rod
9400 |
Wood/ Steel |
4' x 10' |
Devices are panic listed only |
Surface applied
(2) point latching
|
|
Surface Vertical Rod
(Less Bottom Rod)
9400 LB |
Wood/ Steel |
4' x 10' |
Devices are panic listed only |
Surface applied
(1) point latching
|
|
Mortise
9500 |
Wood/ Steel |
4' x 10' |
Devices are panic listed only |
(2) independent active doors with
removable mullion; (1) point
latching. |
|
Mortise
F9500
|
Steel |
4' x 10' |
3 Hour |
Wood |
4' x 8' |
1-1/2 Hour |
Wood |
4' x 10' |
*1/3 Hour |
|
Questions and Answers
Q: Can a 9400 have the latch retraction function installed A: Yes indeed on the
Dorma 9400 Surface Vertical Rod Exit Devices
You are permitted to have latch retraction on the device as seen on page 5 of the link to the product brochure as seen here:
Download File The ES - Latch Retraction requires that you add the letter ES as an option when ordering the item. A common part number for this would be ES x 9400B x YR09C x 426/439 x RHR x 605
Is there a follow up question that we can perhaps attempt to answer? We take deep pride in our technical expertise (something Amazon can not provide) as we know it separates us from our competition, so don't hesitate to ask. Please reply to this email or contact our sales department here: Click Here if we can assist you by answering further questions or with entering this order and please let us know if there is anything else we can help with. If this answer was helpful - please consider following us on Twitter Click Here or liking our page on Facebook Click Here Thank you for your consideration.
(Required, used to email you once question is answered.)
Customer Reviews
There are no customer reviews yet.
|
|
|