Rixson's Right Hand Body Pump And Motor Assembly |
|
|
292LAP-R
for 2920, 2925 Low Energy Automatic Door Openers |
|
|
|
|
Introduction
When exterior wind pressures or security issues arise and a floor closer is the best way to close a door but lighter opening forces are desired, the Rixson® 2900 Automatic Opener is the perfect solution. Low energy operators are not designed for high traffic or heavy doors because the mechanical closings inside are not strong enough to control the door. By using a Rixson heavy-duty floor closer (existing or new installation) along with a Rixson 2900 door opener, there is no need for the extra expense of a high energy operator. There is no special templating for either the floor closer or the operator. •The 2900 series is a combination overhead operator, combined with a Rixson 27, or 28 floor closer. It is not meant to be used with anything else, as the door would not close otherwise. If it is an overhead opener/ closer you seek, We suggest contacting Norton Door Controls. |
Specifications
Heavyweight high-traffic doors that require automatic opening shall use the low energy operator in conjunction with a heavy-duty floor closer. Operator shall be for opening of door only. Door shall be installed in the floor and shall have separate
and independent closing speeds with back check turned to lightest setting. Door controls (interior/exterior) for swinging doors shall be low energy operators. Door closing force shall be adjustable to ensure adequate closing control. Door operator shall have an adjustable backcheck feature to cushion the door opening speed if opened violently. Low energy operation to cycle the
door open as controlled by the body/pump and motor assembly adjustments. Power operator unit shall provide
conventional door closer opening and closing forces unless the power operator motor is activated by an initiating device. Motor assist shall be adjustable from 0 to 30 seconds in 5 second increments. Motor assist shall restart the time cyclem with each activation of the initiating device. Unit shall have a three-position selector mode switch that shall permit unit to be switched “ON” to monitor for function activation, switched to “H/O” for indefinite hold open function or switched to “OFF,” which shall deactivate all control functions but will allow standard door operation by means of the internal mechanical closer. Door control shall be adjustable to provide compliance with the requirements of the Americans with Disabilities Act (ADA) and ANSI standards A117.1 and A156.19. |
 |
RH-PUSH UNITS:
• Rotate the ELS Board Pulley Counter-Clockwise unit hard stop is reached.
• Depress and hold Black Button on the ELS Board. While depressing button, turn power input to unit “ON” and continue
depressing button until the ELS Board LED flashes three (3) times. The installer then has three (3) seconds to release the
button after the LED flashes.
• Slowly rotate ELS Board Pulley Clockwise (away from hard stop) until the LED on the ELS board lights. Note : Pinion pulley
should be rotating with the ELS Board Pulley during this step.
• Hold the Pinion Pulley stationary while tightening the pinion timing pulley screwwith a 5/32 hex wrench.**
• The ELS board is nowcalibrated for a RH-PUSH Unit.
**NOTE: If LED should turn off during the above procedure without any significant movement of ELS Board Pulley, this is not a problem. The timing zone range is large enough to allow for slight movement of ELS Board pulley during tightening of pinion timing screw.
Note: The ELS board is factory-calibrated without any pre-load on the pinion. When the unit is properly installed, and there is pre-load on the pinion, the light on the ELS board will not be lit. This is not a problem. The LED is simply intended to set the ELS Board Pulley in the appropriate “timing zone”. |
Requirements
• Power input to 2900 Series door opener must be 120 VAC (60Hz) to terminals HOT and COM at terminal strip T1. Terminal
GND is earth ground.
• All wiring must conform to standard wiring practice in accordance with national and local wiring codes.
• Note: Unless otherwise noted, all dimensions are given in inches (millimeters).
• Minimum frame face 2" (51mm).
• Minimum ceiling clearance 4-1/8” (104.8mm).
• Minimum suggested and required material thickness for hollow metal frames (skin plus reinforcement) is charted on page 3.
• For wiring refer to Wiring Instruction WI2900 (02-03).
• Hand of unit and hand of door must be the same. Hand of unit is not reversible.
• Door must be hung on 3/4" (19mm) pivots and floor closer. A separate door and frame preparation template will be supplied
for other conditions.
• Door thickness must be 1-3/4" (44mm) minimum.
• Door must swing freely through the entire opening and closing cycle before beginning the installation.
• Use of a supplemental door stop is always recommended.
|
|