Von Duprin 2227DT 210DT / 230DT

copy to clipboard

Von Duprin 2227DT Surface Vertical Rod

enlarge
enlarge
× This image is for a similar product but it will differ in size, color and/or other attributes.
Von Duprin 2227DT Surface Vertical Rod
More from Von Duprin
Price: $1,246.66 USD
Ships From
  Volume Price Information  
 Buy 12 or more and pay $1,184.33 each (save 5.00%
 Buy 36 or more and pay $1,121.99 each (save 10.0%
 Buy 72 or more and pay $1,059.66 each (save 15.00%
Comments (Optional)
In Stock (Minimums Apply):
For quantities beyond the "In Stock" above, the item(s) ships in 2-3 business days.
Additional Declarations - This manufacturer has an order minimum of $85.00 - if your total is less than this amount, the lead time approximately 2-3 weeks before it would ship. Simply exceed this minimum order amount so that we can drop ship the material to your location.

1-773-809-3667

Sales
Technical Support
Product Description:
arrow logo Von Duprin 2227DT Surface Mounted Vertical Rod Device (No Cylinder)
  • Device: Functions Ships ready for all functions; EO, NL, TP, K, L
  • Device Handing: Non-Handed
  • Device Lengths: 3’ (914mm)
  • Door Height: 7’ (2134mm) – standard door height. Extension rods available for door heights up to 10’. 12" (205mm) 36" (914mm).
  • Strikes: 299F – Dull Black.
  • Dogging Feature: Hex key dogging standard.
  • Fasteners & Sex Bolts: Includes 1-3/4" (19mm) – 2-1/4" (57mm) Wood & Metal Doors.
  • Latch Bolt: Deadlocking Anti-friction Top and Bottom Bolt, 5|8" (16mm) throw.
  • Device Centerline from: 39 13/16" (1011mm)
  • Door Undercut: 1/4" (7mm) from finished floor recommended, 3/4" (19mm) maximum or 1/8" (3mm) from threshold.
Options
210DT (no cylinder)
230DT (no cylinder)
Detailed Image

Questions and Answers
Q: What would keep the vertical rod exit devices top latch from being held retracted in the open position?
A: The following items may cause the exit devices top latch from being held in the retracted position.
  • 1. The top or bottom rods are out of adjustment.
  • 2. The top latch hold back feature is defective.
  • 3. The top latch might be a pullman latch which has no hold back feature.

    Following exit devices 2227/F, 33/3527A/F, 33/3547A/48A/F, 98/9927/F and 98/9947/48/F have similar rod adjustment procedures. <> All top latches control the bottom latch assemblies. When door is in open position top latch should stay in retracted position and bottom latch should be held up by top latch being held in retracted position. If top latch is not staying retracted follow the installation instruction rod adjustment procedure.

    33/3547A Rod adjustment instructions as see here:

    Download File

    2227 Rod adjustment instructions as see here:

    Download File

    98/9927/F Rod adjustment instructions as see here:

    Download File

    33/3527A/F Rod adjustment instructions as see here:

    Download File

    98/9947 Rod adjustment instructions as see here:

    Download File

    98/9947WDC Rod adjustment instructions as see here:

    Download File

  • (Required, used to email you once question is answered.)
    • Watch Expert Advice on YouTube
    • Corporate Members of DHI
    • Member of NFPA.
    • Follow us on Facebook
    • AAADM Certified!
    • ALOA Certified!
    • Follow us on Twitter
    • DHI FDAI EDA Inspector
    • AIA
    • Follow us on Pinterest
    • ARL
    • Intertek Logo