Q: Do you have specs or a manual for this interface module? Need to see if it will work for my application. Thanks!
A: The Wiring Diagram for this unit (everything we have), can be reviewed here:
Download File
Is there a follow up question that we can perhaps attempt to answer? We take pride deep in our technical expertise, as we know it separates us from our competition, so don't hesitate to ask.
Please reply to this email or contact our sales department here:
Click Here
if we can assist you by answering further questions or with entering this order and please let us know if there is anything else we can help with.
Q: How can this be used to make a door activate to open and activate to close.
A: Please provide a full operational description so we can make a product suggestion for you - also what door unit are you working on?
Q: ABS, Thank you for your prompt response, a door tech had installed safety stall door mounted sensors on a DOM Sr. Swing dual egress pair, but then found the existing analog Sr. Swing control did not have safety stall inputs, but I found another model that does, therefore problem solved. So are you monitoring Google for door questions? How did you come to respond to my question? Where are you located? I am in California. Would you have been able to answer my question?
A: Did you have to move to a high energy manufacturer to get the sensors added? The LCN material is all "low-energy" which is defined as an opening specifically without sensors. As soon as you add sensors, it is now "High-Energy" and now must be in compliance with ANSI A156.10 and inspected annually by an AAADM certified individual.
We are in Naples Florida and do attempt to respond to questions, technical in nature when posted online.
Q: ot it. FYI, the door is still low energy using push plates and fob readers for activation, and the sensors are cut off when the door closes. I myself, and all of our tech's are AAADM certified. This equipment is older Doromatic low energy but this hospital does have Astroswing equipment too. My actual question was, what model of DOM Sr Swing control box allows safety stall input, ie Super Nova. Thank you for your input, I cannot continue the email thread. Have a nice day sir.
A: We have no experience with the DOM line whatsoever - sorry. I have taken a closer look at A156.10 and would like to know more about your actual deployment of sensors and the application if you will indulge the professional curiosity as I am concerned your install may run afoul of a safe code compliant installation.
Q: Hello, working on a double door install, can I power two, M62 magnalocks off of terminals 2 and 3 , Common and N.O ? If so do I wire them in series, or parallel? Tried to do this and one lock works but will not activate the second lock , bench tested both locks they work with 24vdc, thank you for your time..
A: The module is rated for 10amps as long as the 2 mag locks do not exceed the amp rating it should work simultaneously. We however do not recommend running 2 locks off one module.