Architectural Builders Supplyer Inc. / ABSupply.net

Home   |   Welcome Guest!   |   Sign In?   |   My Account   |   Contact Us   |   Tracking   |  
                                        
Order online or call us 844-809-3667
Shopping Cart
Items in Cart: 0 Items Sub Total: $0.00 View Cart Checkout


Loading....
Search
Advanced Search
    Home > Bathroom Hardware > Hand & Hair Dryers > Surface Mounted > Push-button Activated > Bobrick B-731 115V AirCraft TouchButton Hair Dryer Surface-Mounted

 
Bobrick B-731 115V AirCraft TouchButton Hair Dryer Surface-Mounted
 

B-731 115V

Bobrick B-731 115V AirCraft TouchButton Hair Dryer Surface-Mounted

 
Manufacturer: Bobrick
Price: $0.00
 
 
 
 
 
 
Discontinued Item
Out of StockThis item is discontinued, we are unable to provide technical support and have no inventory remaining on hand. This item is kept in the database for informational purposes only.
Similar Product Video
This product review video is for a similar product but it will differ in size, color and/or other attribute. We still feel the video will be of value to you.
Email Friend
This item ships from CA.
 
400 Series Door Closer
DISCONTINUED -
Bobrick B-731 115V Touch Button Hair Dryer
Bobrick
Bobrick
Bobrick
Bobrick
Bobrick
Bobrick
Item # Description
B-731 115V Bobrick B-731 115V Surface-Mounted AirCraft® Touch Button Hair Dryer
Specifications:
Vitreous enamel cast iron cover, white only
Bobrick
80-second drying cycle.
Bobrick
115V AC, 20 Amp, 2300 Watts, 50/60 Hz, or 208-240V, AC, 9-10 Amp, 1900-2300 Watts, 50/60 Hz, VDE approved and CE marked
Bobrick
Limited warranty: motor brushes for 3 years; all other parts for 10 years
Bobrick
Patented

___

Questions ?

CALL: 877-631-9411

"Bobrick copyrighted product images are used with the permission of Bobrick Washroom Equipment, Inc."
Installation Instructions:

Wall Preparation: Provide framed rough wall opening 13-3/4'' wide x 9-1/2'' high (350 x 240mm). Minimum recessed depth required to finish face of wall is 3-3/4'' (95mm). Allow clearance for construction features that may protrude into rough wall opening from opposite wall. Coordinate with mechanical engineer to avoid pipes, vents, and conduits. If installed in plaster wall, it is recommended that opening be grounded on all four sides with metal plaster trim. If unit projects above top of wainscot, provide aluminum channel or other filler to eliminate gap between flange of mounting box and finish face of wall. If two units are installed back-to-back, a sound-barrier is recommended between units. Provide shims between framing and mounting box at all points indicated by an S, then secure with four #10 (M4.8) screws (not furnished). Provide electrical service from nearest distribution panel to recessed mounting box in conformance with local electrical codes

Materials:
Cover — One-piece, minimum 1/8'' (3mm) thick, grey iron-casting is finished in high-gloss, acid-resistant, multicoat vitreous
enamel. Equipped with a two-position, self-returning, chrome-plated air-outlet nozzle. Graphic operating instructions are
permanently fused with vitreous enamel cover for maximum vandal- and wear-resistance. Air-outlet opening is equipped with
vandal-resistant grille. Cover is secured to base unit with two concealed, vandal-resistant, recessed hex-screws.
Recessed Mounting Box — 16-gauge (1.5mm) steel with baked enamel finish. Rust-resistant.
Base Unit — One-piece aluminum casting. Incorporates concealed, vandal-resistant air-inlet vanes on both sides and
bottom.
Motor — Universal, 1/10 hp, 6200 rpm, on resilient mounting. Sealed ball bearing at drive-shaft end and self-lubricating
sleeve bearing at nondrive end. Equipped with automatic thermal-overload switch.
Fan — Dynamically balanced, single-inlet centrifugal fan is mounted on motor shaft; directs airflow through heating element
at 150 cfmHeating Element — Coiled nickel-chrome heating element is mounted in mica frame and protected by an automatic
thermal-overload switch. Heating element, which is located on inlet side of fan, heats air without hot spots — inaccessible to
vandals.
Electronic Control — Infrared sensor automatically turns dryer on when hands or self-returning nozzle are held under
air-outlet opening and across path of sensor. Remove hands or release self-returning nozzle from path of sensor and dryer
stops. Electronic sensor has automatic shutoff approximately 1-1/2 minutes after dryer turns on if an inanimate object is
placed across air-outlet opening. After inanimate object is removed, electronic sensor automatically resets itself and dryer
operates normally
  Architectural Builders Supply product suggestions:  
 
 
 
Bobrick B-731 230V AirCraft TouchButton Hair Dryer Surface-Mounted
 
DISCONTINUED - Bobrick recessed automatic hand dryer
 
Price: $0.00
 
 
 
 
 
Bobrick B-708 115V AirGuard Automatic Hand Dryer Cast Iron Cover
 
Surface-mounted automatic hand dryer
 
Price: $1,292.03
 
 
Questions and Answers
There are currently no questions or answers.
Customer Reviews
There are no customer reviews yet.
Be the first to Write a Review

Check out our helpful video gallery.

Sales Tax only on purchases in Illinois. Some exclusions apply.  Click for details.